The Rockwell Automation 2090-CSBM1E1-18AF26 is a Kinetix cable designed for use in single motor applications with brake wires. It is part of the 2090 Series and features a single DSL (digital signal line) design. The cable is made of TPE (thermoplastic elastomer) material, which provides continuous flexibility and resistance to chemicals and mechanical stress. It has a continuous bend radius of 10 times the cable diameter, making it suitable for applications where the cable may be bent or flexed during operation.
Technical Specifications
- Construction:
- Outer diameter: approximately 15 mm
- Core color: white
- Cable length: 9 meters
- Drive-end connector type: drive end, extension receptacle
- Number of cores: 8
- With protective conductor: yes
- Core identification: color
- Color outer sheath: orange
- Conductor material: copper
- Conductor surface: tinned
- Color cable code: RAL2003
- Core color: white/blue
- Motor-end connector type: single speedTec DIN connector
- Electrical:
- AWG size: 18
- Nominal voltage U: 1000 V
- Cable type: single motor power with brake wires
- Cable description: power with brake wires: 1000V hybrid cable with four power, two feedback (digital communication), and two brake conductors
- Mechanical:
- Nominal cross section conductor: 0.82 mm²
- Nominal cross section conductor (AWG): 1.62 kcmil
- Cable style: continuous-flexible
- Weight, approx: continuous-flex, extension cable: 0.228 kg/m
- Twisted cores: no
- Accessory component: cable
- Continuous bend radius: continuous flex: 10 times the cable diameter
- Features: low capacitance design to maximize system power density, speedtec connection system, encoder communication data pair with noise rejection, TPE jacket with mechanical and chemical properties, cable features overall tinned copper braid with aluminum/polyester insulation
- Environmental:
- Max. conductor temperature: 105 °C
Documentation
The documentation available for this product includes technical data sheets and specification sheets. These documents provide detailed information on the cable's construction, electrical and mechanical specifications, and environmental conditions. They are available from the manufacturer's website or through authorized distributors.