The part number 2090-CSBM1DF-14AA32 is a type of cable designed by Rockwell Automation for use with their Kinetix 5000 drive families. It is a single motor power cable with a SpeedTec DIN connector, specifically optimized for use with these drives. The cable features a continuous-flexible design, which allows for flexibility and durability in various industrial settings.
Technical Specifications
-
Construction:
- Outer diameter: approximately 17 mm
- Core color: White
- Cable length: 32 meters
- Drive-end connector type: Drive-end, without connector kit, flying-lead (optimized for Kinetix 5500)
- Number of cores: 8
- With protective conductor: Yes
- Core identification: Color
- Colour outer sheath: Orange
- Conductor material: Copper
- Conductor surface: Tinned
- Color cable code: RAL2003
- Core color: White/blue
-
Electrical:
- AWG size: 14
- Nominal voltage U: 1000 V
- Cable type: Single motor power with brake wires
- Cable description: Power with brake wires: 1000V hybrid cable with four power, two feedback (digital communication), and two brake conductors
-
Mechanical:
- Nominal cross section conductor: 2.08 mm²
- Nominal cross section conductor (AWG): 4.1 kcmil
- Cable style: Continuous-flexible
- Weight, approx: Continuous-flex, power with brake wire: 0.289 kg/m
- Twisted cores: No
- Accessory component: Cable
- Continuous bend radius: Continuous flex: 10 times the cable diameter
- Features: Low capacitance design to maximize system power density, speedtec connection system, encoder communication data pair with noise rejection, TPE jacket with mechanical and chemical properties, cable features overall tinned copper braid with aluminum/polyester insulation
-
Environmental:
- Max. conductor temperature: 105 °C
Documentation
- Technical Data: KNX-TD004
Troubleshooting and Programming
- Troubleshooting: The documentation provided does not include troubleshooting information specific to this part number. However, general troubleshooting guides for similar products can be found on the Rockwell Automation website.
- Programming: The programming of this cable is not a function of the cable itself but rather of the devices it connects. For programming information, refer to the documentation for the devices connected to the cable.
Installation
- Installation: Installation of this cable is standard for industrial cables. Ensure proper grounding and insulation to prevent electrical shock and damage to the cable. Follow the manufacturer's guidelines for installation and ensure compliance with local electrical codes.