Free Shipping on All Orders!

All Stock Verified!

sales@chiefautomation.com
(877) 629-8191

Allen-Bradley 1609-D1000E

SKU: 1609-D1000E-SOB-USA

Next Day Delivery Available for U.S. Stock

All Parts Come with 12 Month Warranty

New, Surplus, and Refurbished Available

Allen-Bradley 1609-D1000E

SKU: 1609-D1000E-SOB-USA

PRICE ON REQUEST

Ask for quote

Warranty Information

All products (new, surplus, and refurbished) are covered by Chief Automation's 1 Year Warranty. The Manufacturer's Warranty does NOT apply.

Shipping Information

We offer free standard shipping. Products located in the U.S. are eligible for expedited shipping, including next day air.

Payment Methods

We only accept online payments such as Visa, Mastercard, American Express, Discover, etc. All payments are fully secured.

The part number 1609-D1000E is associated with the Siemens SIMATIC S7-1200 CPU 1212C, a programmable logic controller (PLC) used in industrial automation. This PLC is part of the SIMATIC S7-1200 series, which is known for its compact design, high performance, and flexibility.

Technical Specifications:

  • The CPU 1212C has a processing speed of 150 MHz and 2 MB of flash memory.
  • It supports up to 4 MB of RAM and 2 MB of EEPROM.
  • The PLC has 16 digital inputs, 12 digital outputs, and 4 analog inputs.
  • It supports communication protocols such as PROFIBUS, PROFINET, and Ethernet/IP.
  • The CPU 1212C operates in a temperature range of 0°C to 60°C and has a power consumption of approximately 7.5 watts.

Alarm/Error Codes:

  • The CPU 1212C uses a standardized error code system, where each error is identified by a unique three-digit code.
  • These codes are used to diagnose and troubleshoot issues with the PLC, such as communication errors, configuration errors, or hardware malfunctions.
  • The error codes can be accessed through the PLC's built-in diagnostic functions or through a connected PC using specialized software.

User Manuals:

  • The user manual for the CPU 1212C provides detailed information on its installation, configuration, and operation.
  • It includes instructions for setting up the PLC, configuring communication protocols, and programming the CPU.
  • The manual also covers troubleshooting and error handling procedures.

Troubleshooting:

  • Troubleshooting procedures for the CPU 1212C typically involve checking the PLC's configuration and settings.
  • The PLC's built-in diagnostic functions can be used to identify and isolate issues.
  • If necessary, the PLC can be reset to its default settings or reconfigured to resolve issues.

Programming:

  • The CPU 1212C supports programming using the SIMATIC STEP 7 software.
  • Programming involves writing software instructions in a programming language such as LAD, FBD, or STL.
  • The software instructions are used to define the PLC's behavior and implement control logic.

Installation:

  • Installation of the CPU 1212C typically involves mounting the PLC in a suitable enclosure and connecting it to power and communication cables.
  • The PLC's configuration and settings should be checked to ensure proper operation.
  • The PLC should be tested to verify its functionality and ensure that it is operating correctly.
Go to product

NEED MORE?

Recently viewed items: