Allen-Bradley 1609-B1000N

SKU: 1609-B1000N-SOB-USA

PRICE ON REQUEST

Ask for quote

Warranty Information

All products (new, surplus, and refurbished) are covered by Chief Automation's 1 Year Warranty. The Manufacturer's Warranty does NOT apply.

Shipping Information

We offer free standard shipping. Products located in the U.S. are eligible for expedited shipping, including next day air.

Payment Methods

We only accept online payments such as Visa, Mastercard, American Express, Discover, etc. All payments are fully secured.

Description of Rockwell Automation 1609-B1000N

The Rockwell Automation 1609-B1000N is a 1000 VA, 120V AC input/output uninterruptible power supply (UPS) designed to provide a reliable backup power source for critical applications. It is part of the Allen-Bradley 1609 series of UPS systems from Rockwell Automation.

Technical Specifications

The technical specifications for the 1609-B1000N include:

  • Input/Output Specifications:
    • Input: 96-138VAC
    • Output: 120VAC
    • Capacity: 1000 VA / 600W
  • Power Supply:
    • Power Supply: Bulletin 1609-B
    • Type: Sealed Lead Acid Battery
    • Battery Pack Run Time: ≥2 min (at 25 °C, full load = 600 W, PF = 0.6...0.75)
  • Safety and Compliance:
    • Regulatory Safety: UL1778, CSA C22.2 No. 107.3-05, EN/IEC62040-1
    • EMC: FCC and CE (Class A) Markings
    • UL, cULus, FCC, CE

User Manual and Documentation

The user manual for the 1609-B1000N is available as publication number 1609-UM009D-EN-P, dated February 2021. This document provides detailed information on the technical specifications, installation, and troubleshooting procedures for the UPS.

Troubleshooting and Error Codes

The user manual includes troubleshooting procedures for common issues such as:

  • UPS Disconnect: Check the 1609-ENET LEDs for the communication status and the operation of UPS.
  • Buzzer Alarm: Verify the type of fault from the Status Indicators or the LEDs on the UPS for further troubleshooting.
  • Input Out Of Range: Verify that the input utility voltage is within the UPS input specification.
  • Battery Low: Charge the batteries for 24 hours. If the batteries still indicate that they are low, replace the batteries.
  • Battery Depleted: Charge the batteries for 24 hours. If the battery status still indicates Battery Depleted, new batteries are required.
  • Battery Need Replace: Replace the batteries.
  • Test In Progress: Do not interrupt the UPS testing.
  • Test Fail: The UPS has detected that the battery is bad.

Installation and Programming

The installation and programming procedures for the 1609-B1000N are detailed in the user manual. The manual provides instructions on how to install the UPS, connect it to the power source and load, and configure its settings for optimal performance.

Conclusion

The Rockwell Automation 1609-B1000N is a reliable and efficient UPS designed for critical applications. It offers a range of features, including technical specifications, user manual, troubleshooting procedures, and safety compliance. The UPS is designed to provide a secure backup power source, ensuring continuity of operations in the event of a power outage.