Complete Guide to Configuring PanelView Plus 7 Standard Terminals Settings
Configuring Terminal Settings for PanelView Plus 7 Standard Terminals
The PanelView Plus 7 Standard Terminals are powerful tools for industrial automation, providing operators with essential controls and monitoring capabilities. Configuring these terminals is crucial for optimizing performance and ensuring seamless integration with other system components. This guide provides detailed instructions on configuring the terminal settings of the PanelView Plus 7 Standard Terminals, covering options within FactoryTalk View ME Station, Ethernet settings, controller address configurations, and more.
1. FactoryTalk View ME Station
The FactoryTalk View Machine Edition (ME) Station is a software environment that allows users to create and run Human-Machine Interface (HMI) applications. It offers a range of features to simplify the configuration and operation of PanelView Plus 7 terminals.
- Loading and Running Applications: Navigate to the application loader within FactoryTalk View ME Station, select the desired application, and choose Load. After loading, the application will be ready to run, enabling operators to interact with the control system through the terminal.
- Desktop Access: Desktop access allows users to exit the HMI environment and access the Windows CE operating system for advanced configurations and troubleshooting. This feature can be enabled or disabled based on security requirements.
Enabling and Disabling Desktop Access
To enable desktop access, navigate to the Terminal Settings menu, and select Desktop Access. Follow the prompts to enter the administrator password and enable the feature. To disable desktop access, repeat the steps and choose the disable option.
Configuring Start-up Options
Start-up options can be customized to suit operational needs. Key configurations include:
- Disable FactoryTalk View ME Station on Startup: This option prevents the system from automatically launching the HMI environment, allowing users to perform other tasks.
- Enter Configuration Mode on Startup: This setting enables the terminal to boot into configuration mode, providing immediate access to system settings and configurations.
- Run the Loaded Application on Startup: Automatically runs the last loaded application upon startup, ensuring continuous operation without manual intervention.
2. Configuring Ethernet Settings
Configuring Ethernet settings is essential for establishing reliable network connections. PanelView Plus 7 Standard Terminals support various network topologies such as Device Level Ring (DLR), Linear, and Star. The steps to configure Ethernet settings are as follows:
Set the Ethernet Address of the Terminal
To set the Ethernet address, access the Terminal Settings menu, navigate to the Network tab, and select Ethernet. Enter the desired IP address, subnet mask, and gateway information. Confirm the settings to apply the changes.
Set the Ethernet Link Speed
The Ethernet link speed can be set to match the network's requirements. In the Ethernet settings menu, select Link Speed and choose from available options such as 10 Mbps, 100 Mbps, or auto-negotiation. Save the settings to update the configuration.
Configure the Ethernet Ports
PanelView Plus 7 terminals may come with single or dual Ethernet ports. To configure these ports, navigate to the Ethernet settings, select the specific port, and enter the necessary parameters such as IP address and subnet mask. For dual-port models, ensure both ports are correctly configured to avoid network conflicts.
3. Configure Controller Address
Configuring the controller address is crucial to establish communication between the terminal and the PLC. This is done by:
- Opening the Terminal Settings menu.
- Selecting Controller Address and inputting the address corresponding to the connected PLC.
- Ensuring the address format and parameters match the PLC settings to enable seamless communication.
4. Managing Files on the Terminal
The file management capabilities on the PanelView Plus 7 terminals allow users to copy, delete, and manage files effortlessly. Follow these steps:
Copy Files on Terminal
To copy files, navigate to the File Management menu, select Copy, choose the source file, and specify the destination. Confirm the operation to copy the file.
Delete Files from Terminal
To delete files, access the File Management menu, select Delete, and choose the file you wish to remove. Confirm the deletion to free up storage space on the terminal.
5. Soft Keyboard and Other Utility Settings
The soft keyboard is an on-screen utility that facilitates data entry in environments where physical keyboards are impractical. To access the soft keyboard:
- Navigate to the Terminal Settings menu.
- Select the Input tab and enable the soft keyboard option.
- The keyboard will appear on-screen, allowing for text input directly through the terminal's touch interface.
PanelView Plus 7 Standard Terminals provide several other utility settings to enhance operation and user experience:
- Display Brightness and Contrast: Adjust these settings within the Display menu to optimize visibility based on ambient lighting conditions.
- Date and Time Configuration: Set the terminal's date and time by navigating to the Clock menu and entering the correct values. This ensures accurate time stamps in logs and reports.
Conclusion
Configuring the PanelView Plus 7 Standard Terminals is a critical task that empowers operators to customize the system according to their specific needs. By following the outlined procedures for FactoryTalk View ME Station, Ethernet settings, controller addresses, and file management, users can achieve optimal performance and reliability in their industrial automation applications. Regularly revisiting and updating these configurations as needed will support ongoing system integrity and operational efficiency.
For further details, refer to the PanelView Plus 7 Standard Terminals User Manual, which provides comprehensive instructions and guidelines for all configuration tasks【18:0†source】【18:17†source】.