How to Configure Your PanelView 1000 Operator Terminal: Step-by-Step Guide

Configuring PanelView 1000 Operator Terminals

Power-Up Functions

To begin configuring your PanelView 1000 operator terminal, start with the power-up functions. When you power up the terminal, it performs a series of self-tests to ensure proper functionality. These tests include validating memory, checking system hardware, and verifying software integrity. If any errors occur during this phase, they will be displayed on the screen, allowing for quick identification and troubleshooting of issues.

Starting Up the Terminal in Configuration Mode

To enter configuration mode, power off the terminal and power it on again while holding the designated configuration button. This button is typically labeled and located near the terminal display or keypad. Holding this button during power-up will boot the terminal directly into configuration mode, bypassing normal operation.

The Configuration Mode Menu

Once in configuration mode, the terminal will display the main configuration menu. This menu provides access to various settings and options necessary for configuring the PanelView 1000. Navigating the menu is straightforward, using the terminal's keypad or touchscreen interface. Key options within this menu include:

  • System Settings: Adjust system preferences such as language, display settings, and date/time configuration.
  • Network Settings: Configure network parameters to ensure proper communication with other devices and systems.
  • File Management: Manage application files, including uploading, downloading, and deleting files as necessary.
  • Diagnostics: Access diagnostic tools and logs to assist in troubleshooting and maintaining the terminal.

Transferring Application Files

To transfer application files to the PanelView 1000, use a compatible data transfer method, such as a USB drive, Ethernet connection, or serial cable. Follow these steps to transfer files:

  1. Connect the chosen transfer medium to the terminal.
  2. Select the "File Management" option from the configuration menu.
  3. Choose "Upload" or "Download" based on whether you are sending files to or from the terminal.
  4. Follow the on-screen instructions to complete the file transfer process.

Selecting an Application

After transferring the necessary application files, it is crucial to select the correct application for your specific use case. Within the configuration menu, navigate to the "File Management" or "Application Selection" option. Browse through the available applications, select the appropriate one, and confirm your choice to load the application onto the terminal.

Terminal Network Setup for Remote I/O, DH+, and ControlNet Applications

Network configuration is essential for ensuring reliable communication between the PanelView 1000 terminal and other devices or systems. Follow these guidelines based on your specific network setup:

  • Remote I/O: Configure the terminal's network settings to connect with Remote I/O devices. This involves setting the correct I/O addresses and ensuring proper network termination.
  • DH+: For Data Highway Plus (DH+) networks, set the terminal's communication parameters such as baud rate, node address, and network size.
  • ControlNet: In a ControlNet setup, configure the terminal's node address, network update time, and other relevant parameters to ensure seamless integration with ControlNet controllers.

Application Startup

After configuring the network settings and selecting the appropriate application, start the application to begin normal operation. This can be done from the configuration menu by selecting the "Run Application" or "Start Application" option. The terminal will load the selected application and transition to its operational state.

Application Security

To enhance the security of your PanelView 1000 terminal and its applications, configure user access levels and passwords. This ensures that only authorized personnel can access specific configuration settings and critical functions. Navigate to the "Security" or "User Management" section within the configuration menu to set up and manage security parameters.

Setting Time and Date

Accurate time and date settings are crucial for proper logging and time-stamping of events. Within the configuration menu, locate the "System Settings" or "Clock Settings" option to set the correct time and date. Ensure the terminal's time zone is accurately configured to reflect your operational region.

Terminal Response

To optimize the terminal's performance, adjust response settings such as touchscreen sensitivity, keypad response time, and screen refresh rate. Access these options under "System Settings" or "Performance Settings" within the configuration menu. Fine-tuning these parameters can enhance user experience and efficiency.

Aligning the Screen

For touchscreen terminals, regular screen alignment is essential to maintain accurate touch response. Follow these steps to align the screen:

  1. Select the "Touch Screen Alignment" option from the configuration menu.
  2. Follow the on-screen instructions to touch specific points displayed on the screen.
  3. Complete the alignment process by confirming the calibration adjustments.

Printing

To print reports or logs directly from the PanelView 1000 terminal, connect a compatible serial or USB printer. Configure the printer settings under "System Settings" or "Printer Setup" within the configuration menu. Ensure the printer is correctly connected and recognized by the terminal before attempting to print.