{"product_id":"6fx1126-4be00","title":"Siemens 6FX1126-4BE00","description":"\u003cdiv\u003e\n    \u003cp\u003eSiemens Part Number 6FX1126-4BE00 is a SITRANS F M magnetic flowmeter, a type of flow meter used to measure the volume flow rate of liquids in industrial processes. The device is designed for use in a variety of sectors, including oil and gas, water treatment, and chemical processing.\u003c\/p\u003e\n\n    \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: The device measures flow rates from 0.1 to 100 m³\/h.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: The accuracy of the flow measurement is ±0.5% of the measured value.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePressure Rating\u003c\/strong\u003e: The device is designed to operate at pressures up to 16 bar.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTemperature Range\u003c\/strong\u003e: It can operate in temperatures from -20°C to 80°C.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: The device requires a 24 V DC power supply.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eAlarm\/Error Codes\u003c\/h3\u003e\n    \u003cp\u003eThe SITRANS F M magnetic flowmeter does not have specific alarm or error codes. However, it is equipped with a variety of sensors that can trigger alarms or errors if there are issues with the device or the process it is measuring. These sensors include:\u003c\/p\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFlow Sensor\u003c\/strong\u003e: The flow sensor detects changes in the flow rate and can trigger alarms if the flow rate falls outside the set range.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e: The temperature sensor detects changes in the temperature of the fluid being measured and can trigger alarms if the temperature falls outside the set range.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePressure Sensor\u003c\/strong\u003e: The pressure sensor detects changes in the pressure of the fluid being measured and can trigger alarms if the pressure falls outside the set range.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eUser Manuals\u003c\/h3\u003e\n    \u003cp\u003eThe user manual for the Siemens 6FX1126-4BE00 provides detailed information on the operation, installation, and maintenance of the device. It includes instructions on how to set up the device, how to configure its sensors, and how to troubleshoot common issues.\u003c\/p\u003e\n\n    \u003ch3\u003eTroubleshooting\u003c\/h3\u003e\n    \u003cp\u003eTroubleshooting the Siemens 6FX1126-4BE00 involves checking the device's sensors and power supply to identify any issues that may be affecting its performance. Common issues that may arise include:\u003c\/p\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFlow Rate Errors\u003c\/strong\u003e: If the flow rate is not being measured accurately, check the flow sensor and ensure it is clean and free of debris.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTemperature Errors\u003c\/strong\u003e: If the temperature is not being measured accurately, check the temperature sensor and ensure it is properly calibrated.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003ePressure Errors\u003c\/strong\u003e: If the pressure is not being measured accurately, check the pressure sensor and ensure it is properly calibrated.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ch3\u003eProgramming\u003c\/h3\u003e\n    \u003cp\u003eThe Siemens 6FX1126-4BE00 is pre-programmed at the factory and does not require any additional programming. However, it can be configured to measure different parameters and set different alarm thresholds through a specialized software interface.\u003c\/p\u003e\n\n    \u003ch3\u003eInstallation\u003c\/h3\u003e\n    \u003cp\u003eThe installation of the Siemens 6FX1126-4BE00 involves mounting the device in a location where it can measure the flow rate of the fluid accurately. This typically involves attaching the device to a pipe or duct and ensuring it is properly secured. The device should be installed in accordance with the manufacturer's installation instructions and local regulations.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Siemens","offers":[{"title":"New Factory Sealed \/ Europe","offer_id":48214097035586,"sku":"6FX1126-4BE00-FS-EU","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New Surplus \/ Europe","offer_id":48213553807682,"sku":"6FX1126-4BE00-NS-EU","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished \/ Europe","offer_id":48212914504002,"sku":"6FX1126-4BE00-R-EU","price":2036.4,"currency_code":"USD","in_stock":true},{"title":"New Factory Sealed \/ USA","offer_id":48929354252610,"sku":"6FX1126-4BE00-FS-USA","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New Surplus \/ USA","offer_id":48929354285378,"sku":"6FX1126-4BE00-NS-USA","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished \/ USA","offer_id":48929354318146,"sku":"6FX1126-4BE00-R-USA","price":0.0,"currency_code":"USD","in_stock":false},{"title":"Refurbished \/ ASIA","offer_id":49365777219906,"sku":"6FX1126-4BE00-R-ASIA","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New Surplus \/ ASIA","offer_id":49365777187138,"sku":"6FX1126-4BE00-NS-ASIA","price":0.0,"currency_code":"USD","in_stock":false},{"title":"New Factory Sealed \/ ASIA","offer_id":49365777154370,"sku":"6FX1126-4BE00-FS-ASIA","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/6892\/1666\/files\/Siemens_Products_a326d3fe-f2b5-4525-bb8f-a2acd19cfed1.png?v=1720812178","url":"https:\/\/chiefautomation.com\/fr\/products\/6fx1126-4be00","provider":"Chief Automation","version":"1.0","type":"link"}